TitleShunt Excited DC MotorBrief IntroductionIn operation, when this series of shunt excited dc motor fails to start, reasons may be: 1) the input cable is disconnected or loose; 2) the motor is overload; 3) motor input voltage is too low; 4) the displacement of brush holder. Thus, methods should be
Shunt Excited DC Motor
Brief Introduction
In operation, when this series of shunt excited dc motor fails to start, reasons may be: 1) the input cable is disconnected or loose; 2) the motor is overload; 3) motor input voltage is too low; 4) the displacement of brush holder. Thus, methods should be adopted to solve this problem: 1) check the wiring; 2) lower the load; 3) increase the input voltage; 4) adjust the position of brush holder.
If the motor's vibration is loud, caused reasons are: 1) the bolts of motor supports are loose; 2) the coupling joints are non-concentric; 3) the motor armature counter balance falls off; 4) the supported (Fan) load is not balanced; 5) the armature fan blade falls off. Treatment methods including: 1) fasten the anchor bolts; 2) re-connect and adjust concentricity; 3) re-correct dynamic balance of armature; 4) re-connect dynamic balance and 5) check and solve the problems should be adopted.
Frame | #82 |
Power Scope | 17~40KW |
Voltage | 110V/220V |
Exciting Mode | Shunt Exciting |
Speed | 1500 rpm, 1000rpm, 750rpm |
Cooling Method | IC01 |
Protection Grade | IP22 |
Insulation Class | B (120℃) |
Duty | S1, S4, S5, S6, S9 |
Mounting Type | IM B3 |