Brief IntroductionThis series of75kW soft startersupports programmable timed stopping time. When this parameter needs to be set, the minimum setting amount is 0.1h, which means that when the soft starter is running, it will stop according to the set stopping method after the specified ti
This series of 75kW soft starter supports programmable timed stopping time. When this parameter needs to be set, the minimum setting amount is 0.1h, which means that when the soft starter is running, it will stop according to the set stopping method after the specified time arrives. The setting range of the parameter is 0-999.9h, and the factory setting is 0.1h.
In network communication, 32 devices can be connected, and the communication address of the current device can be viewed in the upper right corner of the LCD display. Users can set the baud rate and communication address to achieve the purpose of automatic communication. The communication address setting range is 1-32, and the factory value is 1. The communication baud rate setting range is 0, 600; 1, 1200; 2, 2400; 3, 4800: 4, 9600; 5, 19200, and the factory value is 4 (9600).
| Protective Function | |
| Phase loss protection | Disconnects any phase of the mains supply during start-up or operation |
| Running overcurrent protection | Operating overcurrent protection setting: 20~500% |
| Phase current unbalance protection | 0~100% |
| Overload protection | Overload protection level: 10A,10,15,20,25,30,OFF |
| Underload protection | Underload protection level: 0~99%; underload protection action time; 0~250S |
| Start timeout | Start time limit: 0~120S |
| Overvoltage protection | When the mains voltage is higher than 120% of the rated value |
| Under-voltage protection | When the mains voltage is lower than 70% of the rated value |